Cerámica y climatización saludablepaneles cerámicos radiantes en edificios. Condiciones de confort y demanda energética frente a sistemas convectivos
ISSN: 0020-0883
Año de publicación: 2016
Volumen: 68
Número: 544
Tipo: Artículo
Otras publicaciones en: Informes de la construcción
Resumen
Porcelain stoneware is a widely used building material. In recent years, its range of uses has expanded to encompass a new spectrum of innovative and inventive applications in architecture. In this research, we analysed the patented Thermal Ceramic Panel. This consists of a thin porcelain stoneware panel that incorporates a capillary system of polypropylene tubes measuring 3.5 mm in diameter embedded in a conductive ceramic interface. The system works with hot or cold water, producing healthy heating and cooling by means of radiant surfaces. Following an initial prototype test in which panels were placed on the walls of an office, we conducted simulations at the University of Alicante Museum using wall, ceiling and baffle panels, having previously monitored the state of the building. Thermal behaviour parameters were analysed and compared with those of other standard finishing materials, obtaining results for thermal comfort and energy savings in comparison with all-air systems.
Referencias bibliográficas
- (1) ASCER. (2003). Guía de la baldosa cerámica. Castellón, Generalitat Valenciana: COACV, Instituto Valenciano de la Edificación.
- (2) Ruá, M.J., Vives, L., Civera, V., López-Mesa, B. (2010, 15 de febrero). Aproximación al cálculo de la eficiencia energética de fachadas ventiladas y su impacto ambiental. En Proc. of XI Congreso Mundial de la Calidad del Azulejo y del Pavimento QUALICER 10, Castellón. PMCid:PMC2904315
- (3) Cantabella, V., et al. (2010, 15 de febrero). Dinamycs of the Thermal Performance of an Electric Radiant Floor with Removable Ceramic Tiles. En Proc. of XI Congreso Mundial de la Calidad del Azulejo y del Pavimento QUALICER 10, Castellón.
- (4) Stetiu, C., Lawrence Berkeley Nacional Laboratory. (1992). Energy and peak power savings potential of radiant cooling systems in US commercial buildings. Energy and Buildings, 30(2): 127-138. https://doi.org/10.1016/S0378-7788(98)00080-2
- (5) Dynamobel. Manual de climatización tranquila. Tramas Karo. http://www.dynamobel.com/Productos/descargas/ INSTALACIONES/CLIMATIZACION/manual%20tecnico%20climatizacion.pdf.
- (6) Echarri, V., Sánchez, R. (2016). Climatización por superficies radiantes mediante tramas capilares. En Hernández, R., et al. (eds.) Architectura Eco-eficiente, Tomo II. San Sebastián: Servicio Editorial de la Universidad del País Vasco.
- (7) Climate Well 10, V9:3. Reference Material for User & Installation Manuals. http://www.climatewell.com.
- (8) Monné, C., Alonso, S., Palacín, F. (2011). Evaluación de una instalación de refrigeración por absorción con energía solar. Información Tecnológica, 22(3): 39-41. https://doi.org/10.4067/S0718-07642011000300006
- (9) Zamora, M. (2008). Empleo de bombas de calor acopladas a intercambiadores geotérmicos: Proyecto Geocool. Montajes e Instalaciones. Revista técnica sobre la construcción e ingeniería de las instalaciones, 38(426): 66-72.
- (10) Haiwen, S., Lin, D., Xiangli, L. (2010). Quasi-dynamic energy-saving judgment of electric-driven seawater source heat pump district heating system over boiler house district heating system. Energy and Buildings, 42(12): 2424-2430. https://doi.org/10.1016/j.enbuild.2010.08.012
- (11) Li, Z., Songtao, H. (2006). Research on the heat pump system using seawater as heat source or sink. Building Energy & Environment 25(3): 34-38.
- (12) Echarri, V., González, A.B., Pérez, M.I. (2012, 13 de febrero). Refreshing Architectural Spaces by Means of Large-Sized Vertical Ceramic Panels. En Proc. of XII Congreso Mundial de la Calidad del Azulejo y del Pavimento QUALICER 12, Castellón.
- (13) Patente de nº solicitud P201001626. Panel de Acondicionamiento Térmico Cerámico. Víctor Echarri (UA), Elena Oviedo (ASCER) y Vicente Lázaro (ITC).
- (14) Zanelli, C., et al. (2010, 15 de febrero). Porcelain Stonware large Slabs Processing and Technological Properties. En Proc. of XI Congreso Mundial de la Calidad del Azulejo y del Pavimento QUALICER 10, Castellón.
- (15) Beka. (2000). Technical information G0. Berlín: Beka Heiz-undKülmatten.
- (16) Knight, E. (2009). Xaar: innovative inkjet technology for the ceramic tile industry. En Digital decoration of ceramic tiles, pp. 70-73. Italia: ACIMAC.
- (17) Hutchings, I. (2010, 15 de febrero). Ink-jet Printing for the Decoration of Ceramic Tiles: Technology and opportunities. En Proc. of XI Congreso Mundial de la Calidad del Azulejo y del Pavimento QUALICER 10, Castellón.
- (18) Echarri, V., Salvador, M., Ramírez, G., Espinosa, A. (2012, 15 de febrero). Lesiones en Paneles Fenólicos de Madera Baquelizada: Diagnóstico e Intervención. En Proc. of 4.º Congreso de Patología y Rehabilitación de Edificios (PATORREB). Santiago de Compostela: Ed. Colegio Oficial de Arquitectos de Galicia, P2-06.
- (19) Echarri, V., Galiano, A., Pérez, M.I., González, A.B. (2014). Conditioning systems by radiant surfaces: comparative analysis of thermal ceramic panels versus the conventional systems in a museum. WIT Transactions on Engineering Sciences, 83. https://doi.org/10.2495/HT140261
- (20) Fanger, O.P. (1970). Thermal Comfort.Analysis and Applications in Environmental Engineering. New York: McGraw- Hill Book Company.
- (21) Ortega, M., Ortega A. (2001). Calefacción y refrescamiento por superficies radiantes. Madrid: Paraninfo, Thomson Learning.
- (22) American Society of Heating, Refrigeration and Air Condiotioning Engineers. (2010). Handbook of Fundamentals. Atlanta: ASHRAE.
- (23) Sala Lizarraga, J.M. (2012). Transmisión de calor en edificios. En Hernández, R., et al. (eds.), Arquitectura Ecoeficiente, volumen I, capítulo 2. San Sebastián: Servicio Editorial de la UPV/EHU.
- (24) Mosteller, R.D. (1987). Simplified calculation of body-surface area. The New England Journal of Medicine, 317(17): 1098. https://doi.org/10.1056/NEJM198710223171717 PMid:3657876