Validity and reliability of smartphone high-speed camera and Kinovea for velocity-based training measurement
-
1
Universitat d'Alacant
info
ISSN: 1988-5202
Year of publication: 2021
Volume: 16
Issue: 4
Pages: 878-888
Type: Article
More publications in: Journal of Human Sport and Exercise: JHSE
Abstract
The aim of this study was to validate the combination of smartphone high-speed camera and motion analysis software Kinovea methodology (SHSC-Kinovea) to measure kinematic variables of velocity-based training during back squat exercises. Fifteen athletes were voluntarily recruited for the study (age 22.8 ± 2.9 years, height 182.9 ± 8.9 cm, body mass 79.5 ± 9.6 kg). High-speed video recordings with a smartphone at 240 fps were used against a criterion linear force transducer (LPT) for measuring displacement of the barbell (RB), mean velocity (MV), maximum velocity (Vmax) and concentric phase time (CPT). The intra-class correlations coefficient between LPT and SHSC-Kinovea showed almost perfect agreement for consistency (.992, .995, .997, .993) and absolute agreement (.975, .978, .980, .964) for RB, MV, Vmax and CPT, respectively. The mean differences between instruments were 1.11 mm for RB, 0.03 m/s for MV, 0.05 m/s for Vmax and 65.91 ms for CPT, all p < .001. Bland-Altman plots showed low systematic bias ± random error for RB: 1.11 ± 1.50 cm (r2: .006), MV: 0.03 ± 0.33 m/s (r2: .001) and Vmax: 65.91 ± 63.82 m/s (r2: .11), whereas Vmax showed overestimation for the high range of measures: 0.55 ± 0.42 m/s (r2: .31). Pearson’s product moment correlation coefficient showed almost perfect association between all variables: (r = .985 - .990) (p < .001). The SHSC-Kinovea methodology resulted in similar kinematic values than criterion so it can be considered as a trustworthy instrument for measuring velocity-based training.
Funding information
This study was supported by vice-rectorate program of research and knowledge transfer for the promotion of R+D+I at the University of Alicante (Ref. GRE18-19).Funders
-
Universidad de Alicante
Spain
- GRE18-19
Bibliographic References
- Atkinson, G., & Nevill, A. (1998). Statistical Methods for Assesing Measurement Error (Reliability) in Variables Relevant to Sports Medicine. Sports Medicine, 26(4), 217–238. https://doi.org/10.2165/00007256-199826040-00002
- Balsalobre-Fernández, C., Geiser, G., Krzyszkowski, J., & Kipp, K. (2020). Validity and reliability of a computer-vision-based smartphone app for measuring barbell trajectory during the snatch. Journal of Sports Sciences, 38(6), 710–716. https://doi.org/10.1080/02640414.2020.1729453
- Balsalobre-Fernández, C., Kuzdub, M., Poveda-Ortiz, P., & Del Campo-Vecina, J. (2016). Validity and reliability of the PUSH weareble devive to measure movement velocity during the back squat exercise. Journal of Strength & Conditioning Research, 30(7), 1968–1974. https://doi.org/10.1519/JSC.0000000000001284
- Balsalobre-Fernández, C., Marchante, D., Baz-Valle, E., Alonso-Molero, I., Jiménez, S. L., & Muñóz-López, M. (2017). Analysis of wearable and smartphone-based technologies for the measurement of barbell velocity in different resistance training exercises. Frontiers in Physiology, 8(AUG). https://doi.org/10.3389/fphys.2017.00649
- Balsalobre-Fernández, C., Marchante, D., Muñoz-López, M., & Jiménez, S. L. (2018). Validity and reliability of a novel iPhone app for the measurement of barbell velocity and 1RM on the bench-press exercise. Journal of Sports Sciences, 36(1), 64–70. https://doi.org/10.1080/02640414.2017.1280610
- Balsalobre-Fernández, C., Tejero-González, C. M., Campo-Vecino, J. Del, & Bavaresco, N. (2014). The concurrent validity and reliability of a low-cost, high-speed camera-based method for measuring the flight time of vertical jumps. Journal of Strength and Conditioning Research, 28(2), 528–533. https://doi.org/10.1519/JSC.0b013e318299a52e
- Banyard, H. G., Nosaka, K., Sato, K., Haff, G. G., Young, D., John, C. K., & Harry, H. (2017). Validity of Various Methods for Determining Velocity, Force and Power in the Back Squat - Banyard, Nosaka, Sato & Haff 2017.pdf. Science, 5(1), 1–8. https://doi.org/10.1123/ijspp.2016-0627
- Bartlett, J. W., & Frost, C. (2008). Reliability, repeatability and reproducibility: Analysis of measurement errors in continuous variables. Ultrasound in Obstetrics and Gynecology, 31(4), 466–475. https://doi.org/10.1002/uog.5256
- Bland, J. M., & Altman, D. G. (1986). Statistical Methods for Assessing Agreement Between Two Methods of Clinical Measurement. Lancet, 327, 307–310. https://doi.org/10.1016/S0140-6736(86)90837-8
- Bosquet, L., Porta-Benache, J., & Blais, J. (2010). Validity of a commercial linear encoder to estimate bench press 1 RM from the force-velocity relationship. Journal of Sports Science and Medicine, 9, 459–463.
- Courel-Ibáñez, J., Martínez-Cava, A., Morán-Navarro, R., Escribano-Peñas, P., Chavarren-Cabrero, J., González-Badillo, J. J., & Pallarés, J. G. (2019). Reproducibility and repeatability of five different technologies for bar velocity measurement in resistance training. Annals of Biomedical Engineering, 47(7), 1523–1538. https://doi.org/10.1007/s10439-019-02265-6
- Crewther, B. T., Kilduff, L. P., Cunningham, D. J., Cook, C., Owen, N., & Yang, G. Z. (2011). Validating two systems for estimating force and power. International Journal of Sports Medicine, 32(4), 254–258. https://doi.org/10.1055/s-0030-1270487
- Dorrell, H. F., Moore, J. M., Smith, M. F., & Gee, T. I. (2018). Validity and reliability of a linear positional transducer across commonly practised resistance training exercises. Journal of Sports Sciences, 2, 1–7. https://doi.org/10.1080/02640414.2018.1482588
- Drinkwater, E. J., Galna, B., McKenna, M. J., Hunt, P. H., & Pyne, D. B. (2007). Validation of an optical encoder during free weight resistance movements and analysis of bench press sticking point power during fatigue. Journal of Strength and Conditioning Research, 21(2), 510–517. https://doi.org/10.1519/00124278-200705000-00039
- Garcia Ramos, A., Perez-Castilla, A., & Martin, F. (2011). Reliability and concurrent validity of the velowin optoelectronic system to measure movement velocity during free-weight back squat. International Journal of Sports and Coaching, (December), 1–45. https://doi.org/10.1177/1747954118791525
- Góme-Piriz, P. T., Trigo, M. E., Cabello, D., & Puga, E. (2012). Confiabilidad entre instrumentos (T-Force® y Myotest®) en la valoración de la fuerza. RICYDE. Revista Internacional de Ciencias Del Deporte, 8(27), 20–30. https://doi.org/10.5232/ricyde2012.02702
- González-Badillo, J. J., Rodríguez-Rosell, D., Sánchez-Medina, L., Gorostiaga, E. M., & Pareja-Blanco, F. (2014). Maximal intended velocity training induces greater gains in bench press performance than deliberately slower half-velocity training. European Journal of Sport Science, 14(8), 772–781. https://doi.org/10.1080/17461391.2014.905987
- González-Badillo, J. J., Yañez-García, J. M., Mora-Custodio, R., & Rodríguez-Rosell, D. (2017). Velocity loss as a variable for monitoring resistance exercise. International Journal of Sports Medicine, 38(3), 217–225. https://doi.org/10.1055/s-0042-120324
- Hopkins, Will G. (2018). SAS Programs for Analyzing Individual Responses in Controlled Trials. Sportscience, 8, 1–7.
- Hopkins, William G., Marshall, S. W., Batterham, A. M., & Hanin, J. (2009). Progressive statistics for studies in sports medicine and exercise science. Medicine and Science in Sports and Exercise, 41(1), 3–12. https://doi.org/10.1249/MSS.0b013e31818cb278
- Koo, T. K., & Li, M. Y. (2016). A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. Journal of Chiropractic Medicine, 15(2), 155–163. https://doi.org/10.1016/j.jcm.2016.02.012
- Loturco, I., Pereira, L. A., Cal Abad, C. C., Gil, S., Kitamura, K., Kobal, R., & Nakamura, F. Y. (2016). Using bar velocity to predict maximum dynamic strength in the half-squat exercise. International Journal of Sports Physiology and Performance, 11(5), 697–700. https://doi.org/10.1123/ijspp.2015-0316
- Mann, J. B., Ivey, P. A., & Sayers, S. P. (2015). Velocity-based training in football. Strength and Conditioning Journal, 37(6), 52–57. https://doi.org/10.1519/SSC.0000000000000177
- Martínez-Cava, A., Morán-Navarro, R., Sánchez-Medina, L., González-Badillo, J. J., & Pallarés, J. G. (2019). Velocity- and power-load relationships in the half, parallel and full back squat. Journal of Sports Sciences, 37(10), 1088–1096. https://doi.org/10.1080/02640414.2018.1544187
- Pérez-Castilla, A., Feriche, B. B. B., Jaric, S., Padial, P., García-Ramos, A., Perez-Castilla, A., … García-Ramos, A. (2017). Validity of a linear velocity transducer for testing maximum vertical jumps. Journal of Applied Biomechanics, 33(5), 388–392. https://doi.org/10.1123/jab.2016-0142
- Pérez-Castilla, A., Piepoli, A., Delgado-García, G., Garrido-Blanca, G., & García-Ramos, A. (2019). Reliability and concurrent validity of seven commercially available devices for the assessment of movement velocity at different intensities during the bench press. Journal of Strength and Conditioning Research, 33(5), 1258–1265. https://doi.org/10.1519/jsc.0000000000003118
- Pérez-Castilla, A., Piepoli, A., Garrido-Blanca, G., Delgado-García, G., Balsalobre-Fernández, C., & García-Ramos, A. (2019). Precision of 7 commercially available devices for predicting bench-press 1-repetition maximum from the individual load–velocity relationship. International Journal of Sports Physiology and Performance, 14(10), 1442–1446. https://doi.org/10.1123/ijspp.2018-0801
- Pérez-Castilla, A., Rojas, F. J., & García-Ramos, A. (2019). Reliability and magnitude of loaded countermovement jump performance variables: a technical examination of the jump threshold initiation. Sports Biomechanics, (October). https://doi.org/10.1080/14763141.2019.1682649
- Pueo, B. (2016). High speed cameras for motion analysis in sports science. Journal of Human Sport and Exercise, 11(1), 53–73. https://doi.org/10.14198/jhse.2016.111.05
- Pueo, B., Jimenez-Olmedo, J. M., Penichet-Tomas, A., & Bernal-Soriano, M. C. (2018). Inter-rater reliability of trained and untrained raters for measuring jump height with the myjump app. Journal of Physical Education and Sport, 18(2), 821–824. https://doi.org/10.7752/jpes.2018.02121
- Pueo, B., Lipinska, P., Jiménez-Olmedo, J. M., Zmijewski, P., & Hopkins, W. G. (2017). Accuracy of jump-mat systems for measuring jump height. International Journal of Sports Physiology and Performance, 12(7). https://doi.org/10.1123/ijspp.2016-0511
- Pueo, B., & Jimenez-Olmedo, J. M. (2017). Application of motion capture technology for sport performance analysis. Retos. Nuevas Tendencias En Educacion Física, Deporte y Recreación, 32, 241–247.
- Sánchez-Medina, L., Pallarés, J., Pérez, C., Morán-Navarro, R., & González-Badillo, J. J. (2017). Estimation of relative load from bar velocity in the full back squat exercise. Sports Medicine International Open, 01(02), E80–E88. https://doi.org/10.1055/s-0043-102933
- Sanchez Medina, L., & Gonzalez-Badillo, J. J. (2011). Velocity loss as an indicator of neuromuscular fatigue during resistance training. Medicine Science in Sports Exercise, 43(9), 1725–1734. https://doi.org/10.1249/mss.0b013e318213f880